Periodic saved-owner recovery now passes.
OT-168: one Heltec V4.2 and Note20 Ultra pair passes saved-owner authorization, fresh device Snapshot/Ready, app-process persistence, and automatic warm-reset reconnect. The measured 1.493-second interval is BLE link recovery, not full Ready latency. Periodic reconnect is implemented and physically passed after a 65.866-second ROM absence: one empty scan, then automatic recovery during the next scan, without phone input. Link returned 1.220 seconds after reset completion; authenticated Ready was observed within 8.373 seconds.
After three quick retries, the open app waits 15 seconds between five-second saved-owner scans. Explicit disconnect stops recovery. The physical result covers one retained pair; true cold-power recovery, factory-reset erasure, production zero-tap launch, and coherent two-phone/two-Heltec secure-LoRa acceptance remain open. Battery-percentage accuracy and Android interface cleanup are follow-ups; no supported or production-ready release is claimed.
Read the dated test evidence